HyreRemodel

Quick answer

A wall stud is one of the vertical boards, usually 2x4 or 2x6 lumber, that run from the bottom plate to the top plate of a framed wall and carry its load, hold its sheathing and drywall, and make room for wires, pipes and insulation.

Studs are set at regular spacing, most often 16 or 24 inches on center. The building code sets their size, height, spacing and how big a hole they can take.

Quick facts

The key facts about Wall Stud, with sources:

Common sizes
2x4 (1-1/2 by 3-1/2 inches actual) and 2x6 (1-1/2 by 5-1/2 inches actual) 8
Usual spacing
16 or 24 inches on center, set by Table R602.3(5) 1
Minimum grade
No. 3, standard or stud grade lumber 1
Biggest bored hole
60% of stud depth, at least 5/8 inch from the edge 1
Notch limit
25% of depth in bearing walls; 40% in nonbearing walls 1
Cable clearance
Holes for wiring 1-1/4 inches from the stud face, or a steel plate 3
Fireblocking
At floor and ceiling levels and every 10 feet of height 2

Key takeaways

  • A stud is the upright board in a wood-framed wall; plates top and bottom tie the studs together.
  • Most house walls use 2x4 or 2x6 studs at 16 or 24 inches on center, and the code table sets which combination a wall may use.
  • A 2x6 wall holds deeper insulation, which is why many colder climate zones build exterior walls with 2x6 studs.
  • Holes and notches are limited by percentage of stud depth, and the limits are stricter in exterior and bearing walls.
  • Finding, drilling or adding a stud is routine; cutting or removing studs in a bearing wall is a job for an engineer and a permit.

What a stud is, in plain terms

Open any wood-framed wall and you see a row of upright boards. Each one is a stud. A horizontal board at the floor, called the bottom or sole plate, holds their feet.

One or two boards across the top, called the top plate, tie their heads together. Drywall goes on the inside face, and sheathing and siding go on the outside face of an exterior wall.

The 2021 International Residential Code (IRC), the model code most states use for houses, says studs must run in one piece from the bottom plate to the top plate, so they can resist wind and other loads pushing on the face of the wall 1.

Short studs are only allowed around openings: jack studs under a header, and cripple studs above or below a window 1.

A stud name gives its nominal size, not its real size. A "2x4" is about 1-1/2 by 3-1/2 inches once it is dried and planed, and a "2x6" is about 1-1/2 by 5-1/2 inches 8.

That real depth matters, because it sets how thick the insulation can be and how big a hole the code allows.

Studs come in wood and in cold-formed steel. This page covers wood, which frames most homes. Steel studs follow their own section of the code (R603) and their own rules for holes and fastening 1.

System The parts of a framed wall around one stud
Wall studFull-height upright from plate to plate
  • Bottom (sole) plateGives the stud full bearing on the floor
  • Double top plateTies studs together; joints offset at least 24 inches
  • HeaderCarries load over a door or window
  • Jack and king studsSupport and flank the header
  • Cripple studsShort studs above or below an opening
  • FireblockingCloses the cavity at floor and ceiling lines

Every part here appears in 2021 IRC Section R602. The stud is the repeated member; the others close, cap and bridge the row. Source: [1]

How studs carry load and hold a wall together

A stud does several jobs at once. Each one explains a rule you will meet later on this page.

  1. Carrying weight down. In a bearing wall, the roof, ceiling or floor above rests on the top plate. Each stud carries its share straight down to the bottom plate and the floor or foundation below 1.
  2. Resisting wind on the wall face. Wind pushes on the siding and sheathing. The studs act like short beams between the plates, which is why the code limits their unsupported height 1.
  3. Staying straight. A slender stud can bow sideways under load. Sheathing on at least one side, or bridging no more than 4 feet apart, keeps bearing studs from buckling 1.
  4. Holding the finishes. Drywall edges and fasteners must land on framing, so stud spacing also sets drywall thickness and screw spacing 4.
  5. Making a cavity. The space between studs holds insulation, cable and pipe. Its depth equals the stud depth, about 3-1/2 inches for a 2x4 and 5-1/2 inches for a 2x6 8.

Take a stud away, or cut too deep into one, and one of those jobs stops working. That is the reason the drilling and notching limits exist.

Stud sizes and kinds you will see in a remodel

Heights and spacings are the 2021 IRC prescriptive limits for wood studs. Your plans or an engineer may call for something else.
StudActual sizeWhere it is usedCode note
2x31-1/2 by 2-1/2 inchesInterior nonbearing partitions onlyNot allowed in exterior walls; up to 10 ft tall at 16 in. on center 1
2x41-1/2 by 3-1/2 inches 8Most interior walls; exterior walls in milder climatesBearing: 10 ft max height; 24 in. spacing under a roof only, 16 in. with one floor above 1
2x61-1/2 by 5-1/2 inches 8Exterior walls in colder zones, plumbing walls, tall wallsBearing: 24 in. spacing with one floor above, 16 in. with two floors 1
Utility-grade studSame sizes, lower gradeLight-duty wallsMax 16 in. spacing; 8 ft in bearing walls, 10 ft in nonbearing 1
Jack (trimmer) studSame as the wallUnder each end of a headerNumber per end set by the header tables 1
King studSame as the wallFull height beside each openingMinimum count by header span and wind speed 1
Cripple studSame as the wallAbove a header or below a sillAllowed to be short, unlike regular studs 1

Example: how big a hole can go through a 2x4 or 2x6 stud

Remodels add wire, pipe and vent runs to old walls. This table turns the IRC percentages into inches, using actual stud depth. It is arithmetic on the code rule, not a design for a specific wall 18.

Rule (2021 IRC R602.6)2x4 (3-1/2 in. deep)2x6 (5-1/2 in. deep)
Notch, exterior or bearing wall: 25% of depthAbout 7/8 inchAbout 1-3/8 inches
Notch, nonbearing partition: 40% of depthAbout 1-3/8 inchesAbout 2-3/16 inches
Bored hole, any stud: 60% of depthAbout 2-1/8 inchesAbout 3-5/16 inches
Bored hole over 40% in a bearing or exterior studOver about 1-3/8 inches: double the studOver about 2-3/16 inches: double the stud
Edge distance for any holeAt least 5/8 inchAt least 5/8 inch
Hole for electrical cable (no steel plate)Edge at least 1-1/4 inches from the stud faceEdge at least 1-1/4 inches from the stud face 3
Formula Largest allowed bored hole in a wood stud

Maximum hole diameter = 0.60 × actual stud depth (and over 0.40 × depth in a bearing wall, double the stud)

Actual stud depth
3-1/2 in. for a 2x4, 5-1/2 in. for a 2x6
0.60 and 0.40
Limits from 2021 IRC Section R602.6, item 2

The hole edge must also stay at least 5/8 inch from the stud edge, and a hole may not sit in the same section as a notch.

Source: [1] [8]

Two lessons fall out. First, a 3-inch drain pipe cannot pass through a 2x4 bearing wall within these limits, which is one reason plumbing walls are often framed with 2x6 studs.

Second, a hole that is legal for structure may still be too close to the face for wiring; then a 1/16-inch (0.0625-inch) steel plate protects the cable from drywall screws 3.

Where studs show up in a remodel: plans, walls and inspection

On the drawings. Plans for an addition or a basement finish usually note stud size and spacing in a wall section, for example "2x6 at 16 in. o.c." That note decides insulation depth and drywall fastening.

In an opened wall. When a kitchen remodel moves a sink or adds outlets, the trades cut through studs. The inspector looks at those holes and notches during the rough-in inspection, before drywall hides them.

Behind drywall you want to hang things on. Heavy cabinets, grab bars and TV mounts need solid backing. Studs, or blocking added between them, give screws something to bite.

In the quote. A framing line item may say "fur out wall" or "sister studs." Furring adds thin strips to flatten a wall; sistering fastens a new stud beside a damaged one. Ask which walls are affected and whether any are bearing.

Finding studs without guessing

A stud finder, a small magnet that sticks to drywall screws, or the outlet boxes (usually fixed to a stud side) will all locate framing. Measure 16 or 24 inches from the first one you find, then confirm before you drill.

What deeper studs buy you, and what they cost in space

Why builders choose 2x6

  • A deeper cavity for insulation; the 2021 IECC asks for R-20 cavity or R-13 plus R-5 continuous in climate zone 3 and more in zones 4 to 8 7.
  • More room for drain pipes and ducts within the hole limits.
  • Longer allowed spacing in a wall carrying one floor plus a roof: 24 inches versus 16 for a 2x4 1.
  • Taller nonbearing walls: up to 20 feet unsupported versus 14 feet for a 2x4 1.

Trade-offs to weigh

  • Each wall is 2 inches thicker, which takes floor area from rooms.
  • Window and door jambs need deeper extensions to meet the wall.
  • Studs are still thermal bridges; wood conducts heat faster than insulation, so continuous insulation can matter as much as cavity depth.
  • More lumber per foot of wall, even at wider spacing.

What studs cannot do on their own

  • Span an opening. A stud wall cannot carry load over a door or window. A sized header and jack studs do that, per the IRC header tables 1.
  • Resist racking alone. A wall of studs leans like a parallelogram under wind or earthquake load. Braced wall panels and sheathing stop that 1.
  • Stop fire in the cavity. An open stud bay is a chimney. Fireblocking at each floor and ceiling and every 10 feet of height breaks it up 2.
  • Grow taller without limits. Table R602.3(5) caps bearing studs at 10 feet of unsupported height; taller walls need the exceptions or an engineered design 1.
  • Survive long wetting. Wood studs that stay wet can rot and grow mold, so leaks must be stopped and framing dried.

What drives framing cost, and how long studs last

We do not publish framing prices. Lumber markets move quickly and local labor varies too much for a national number to be honest. What we can name are the drivers. Stud size and spacing set the lumber count.

Wall height matters, since taller walls may need bigger studs or engineering. Openings add headers, jack and king studs. Repair work adds labor because old walls must be opened, and in homes built before 1978 painted surfaces may need lead-safe work practices 9.

Hidden conditions often drive change orders: rotted bottom plates near old leaks, past notches that went too far, or studs cut by an earlier owner.

A good scope says who pays when those turn up. Our remodeling cost guide explains how such items move a budget, and the quote comparison tool helps you line up framing scope bid by bid.

Kept dry, wood studs last as long as the house. No warranty applies to the lumber itself; the framing work is covered by your contractor’s workmanship warranty and the inspection record.

How studs get added or changed in a remodel

Who does what, in the usual order, for a new partition or a wall being opened up.

  1. The designer or engineer decides wall locations and tells you which existing walls are bearing.
  2. You or your contractor apply for the permit; most framing changes need one, and the permit checker gives a first read on your project.
  3. The framer lays out plates and marks stud locations at the planned spacing, then stands the wall.
  4. Electricians and plumbers drill and notch within the R602.6 limits, add doubled studs where holes are large, and fit steel plates where cables run close to the face 13.
  5. Fireblocking goes in at floor and ceiling lines and around pipe and wire holes 2.
  6. The inspector checks framing at rough-in, before insulation and drywall.
  7. Insulation and drywall follow, fastened to the studs at the spacing the drywall table allows 4.

Keeping wall framing sound

Studs need no routine care. They need dry conditions and no new damage.

  • Fix leaks fast. EPA advises drying wet materials within 24 to 48 hours to prevent mold 10.
  • Keep a record of holes. Photograph open walls before drywall so the next trade knows where cables and pipes run.
  • Use the right anchor. Screw heavy items into studs or added blocking rather than drywall alone.
  • Check bottom plates in basements and bathrooms during any later work; they are the first part to rot.

Warning signs of damaged or overcut studs

  • Cracks in drywall running from the corners of doors and windows, or doors that start to bind.
  • A wall that bows or a floor that dips along a wall line.
  • Big notches across several studs in a row, often from an old pipe or duct run.
  • Soft or dark wood at the bottom plate, a sign of long-term moisture.
  • Cut studs under a beam or post found when a wall is opened.

Do not cut studs in a bearing wall

Removing or deeply cutting studs in an exterior or load-bearing wall can let the structure above sag or fail.

Have an engineer confirm whether the wall is bearing, get a permit, and let a licensed contractor install temporary shoring and the designed header.

In homes built before 1978, opening painted walls also calls for lead-safe work by a certified firm.

If you find any of these in a bearing or exterior wall, stop work in that area and call a licensed structural engineer or an experienced framing contractor to assess it.

The code rules for studs: 2021 IRC Sections R602 and R302.11

Size, height and spacing. 2021 IRC Section R602.3.1 points to Table R602.3(5).

For a bearing wall of 2x4 studs up to 10 feet tall, the table allows 24 inches on center when the wall carries only a roof and ceiling, 16 inches when it also carries one floor, and no 2x4 option for two floors.

For 2x6 studs it allows 24, 24 and 16 inches in those same three cases. Nonbearing 2x4 walls may be 14 feet tall at 24 inches on center 1.

Grade. Section R602.2 requires No. 3, standard or stud grade lumber, with a narrow allowance for utility grade 1.

Plates. Section R602.3.2 calls for a double top plate with end joints offset at least 24 inches; R602.3.4 requires full bearing on a bottom plate at least as wide as the stud 1.

Holes and notches. Section R602.6 limits notches to 25% of depth in exterior and bearing walls and 40% in nonbearing partitions; bored holes to 60% of depth, at least 5/8 inch from the edge, with doubling over 40% in exterior and bearing walls.

R602.6.1 requires a 16-gauge steel tie when a top plate is cut more than half its width 16.

Fire and wiring. Section R302.11 requires fireblocking at ceiling and floor levels and at most every 10 feet vertically 2. Table E3802.1 keeps cables 1-1/4 inches from stud edges or behind a steel plate 3.

These are model code rules. States and cities adopt an edition and often amend it, so confirm with your building department. Alterations to existing homes may also fall under the International Existing Building Code.

Stud myths that cause problems

Myth A 2x4 is 2 inches by 4 inches.
Reality It is about 1-1/2 by 3-1/2 inches once dried and planed 8. Depth for insulation and holes is 3-1/2 inches.
Myth All studs are always 16 inches apart.
Reality The IRC allows 24 inches in many cases, and requires 16 or less in others, depending on size and what the wall carries 1.
Myth Any hole is fine if it is in the middle.
Reality Bored holes are capped at 60% of depth, and over 40% in bearing walls the stud must be doubled 1.
Myth Interior walls never carry load.
Reality Many interior walls hold up floor or ceiling joists. Have one confirmed before you remove it.
Myth Metal plates are optional.
Reality When a cable hole edge sits closer than 1-1/4 inches to the stud face, the code requires a steel plate or other protection 3.

How your climate zone pushes stud size

The regional variable that most often changes stud choice is the IECC climate zone. Under the 2021 IECC prescriptive table, a wood-frame wall in zones 0 to 2 needs R-13 cavity insulation (or R-10 continuous), which fits a 2x4.

Zone 3 needs R-20 cavity, R-13 plus R-5 continuous, or R-15 continuous. Zones 4 and 5 need R-20 plus R-5 continuous, or R-13 plus R-10 continuous, and zones 6 to 8 have similar options 7.

A 2x6 cavity fits R-20 batts where a 2x4 cannot, which is why cold-climate builders often frame with 2x6. Wind and seismic design categories, set by location, also change bracing and some stud rules. Your building department confirms the edition and zone it enforces.

When stud details should change your plan

Stud details matter most when you are moving plumbing, adding insulation to exterior walls, or changing an opening. In each case, ask early whether the wall is bearing and what size its studs are.

If you are only hanging shelves or adding an outlet in a nonbearing wall, a stud finder and the hole limits above are enough.

If the plan cuts into an exterior or bearing wall, the next step is an engineer’s opinion and a permit.

Our guide to choosing a remodeling contractor covers how to check that a framer holds the right license.

Decision guide Stud decision guide
If You only need to hang something heavy
Then Locate studs and screw into them, or add blocking
If A pipe or cable must cross a stud
Then Stay within 60% hole and 5/8 inch edge limits; plate cables near the face
If A hole over 40% is needed in a bearing wall
Then Double the stud, or reroute
If You want to remove or cut studs in a bearing wall
Then Hire an engineer and pull a permit first

Questions about Wall Stud

How far apart are wall studs?

Most wall studs are 16 or 24 inches apart, measured center to center. The 2021 IRC sets the maximum by stud size and load in Table R602.3(5).

For example, 2x4 studs carrying a floor and roof may be no more than 16 inches apart, while 2x6 studs in the same wall may be 24 inches apart.

What size is a 2x4 stud really?

A 2x4 stud is about 1-1/2 inches by 3-1/2 inches. The name is the nominal size before drying and planing. A 2x6 is about 1-1/2 by 5-1/2 inches. Use the actual depth when you plan insulation thickness or work out how big a hole the code allows through the stud.

How big a hole can I drill in a stud?

Under 2021 IRC Section R602.6, a bored hole may be up to 60% of the stud depth, with its edge at least 5/8 inch from the stud edge.

In exterior or bearing walls, a hole larger than 40% means the stud must be doubled, and no more than two doubled studs in a row may be bored that way.

How deep can you notch a wall stud?

A stud in an exterior wall or bearing partition may be notched no deeper than 25% of its depth, about 7/8 inch on a 2x4. Studs in nonbearing partitions may be notched up to 40%. A hole and a notch may not share the same section of a stud, so space them apart.

Should exterior walls be 2x4 or 2x6?

It depends mostly on climate and insulation. In the 2021 IECC, climate zones 0 to 2 need about R-13 in the wall, which a 2x4 holds. Colder zones call for R-20 cavity insulation or added continuous insulation, which is easier with 2x6 studs. Structure and wall height can also require 2x6.

Why do electricians put metal plates on studs?

The plates protect cables from drywall screws and nails. The code requires a steel plate at least 1/16 inch thick, or other protection, when a cable hole sits less than 1-1/4 inches from the face of the stud. Plumbers use similar plates for pipes near the face.

What is fireblocking between studs?

Fireblocking is solid material, such as 2-inch lumber or 1/2-inch gypsum board, that closes the stud cavity so fire and smoke cannot race up it. The 2021 IRC requires it at floor and ceiling levels and at least every 10 feet of wall height, and around pipe and cable holes at those levels.

Can I remove a stud to widen an opening?

Not without a design. In a bearing or exterior wall, removing studs means adding a header sized from the code tables, with jack and king studs at each end, and usually a permit. An engineer or experienced contractor should confirm whether the wall is bearing before any stud is cut.

What is the difference between a jack stud and a king stud?

A jack stud, also called a trimmer, is a short stud that sits under each end of a header and carries it. A king stud runs full height next to the jack and is nailed to the header end. The IRC tables set how many of each are needed for a given header span.

Sources

  1. ICC, 2021 International Residential Code, Chapter 6 Wall Construction (R602.2, R602.3, Table R602.3(5), R602.5, R602.6, R602.6.1), retrieved .
  2. ICC, 2021 International Residential Code, Chapter 3 Building Planning (R302.11 fireblocking), retrieved .
  3. ICC, 2021 International Residential Code, Chapter 38 Wiring Methods (Table E3802.1), retrieved .
  4. ICC, 2021 International Residential Code, Chapter 7 Wall Covering (Table R702.3.5), retrieved .
  5. ICC, 2021 International Residential Code, Chapter 5 Floors (R502.8.1), retrieved .
  6. ICC PMG Membership Council, CodeNotes: Cutting, Drilling and Notching (based on the 2021 IRC), retrieved .
  7. ICC, 2021 International Energy Conservation Code, Chapter 4 [RE] (Table R402.1.3), retrieved .
  8. Missouri University of Science and Technology, Sizes of Structural Lumber (from NDS Supplement Tables 1A and 1B), retrieved .
  9. U.S. EPA, Lead Renovation, Repair and Painting Program, retrieved .
  10. U.S. EPA, A Brief Guide to Mold, Moisture and Your Home, retrieved .

Expert review

Written by the HyreRemodel Research team. Not yet reviewed by an outside expert. We say so rather than imply a review that has not happened; see our editorial policy.

How the numbers were checked: Stud grade, size, height, spacing, plate and drilling rules were read from 2021 IRC Chapter 6 on ICC Digital Codes and cross-checked against the ICC CodeNotes on cutting, drilling and notching.

Fireblocking comes from R302.11, cable protection from Table E3802.1, and wall insulation levels from 2021 IECC Table R402.1.3. Actual lumber sizes come from a university summary of the NDS Supplement. The inch conversions in the hole-size example are our arithmetic on the IRC percentages. No prices are given.

Suggest a correction. We fix errors and say what changed.